DEVLOG #36
The first full TX1 acceptance run is done now and it failed, but at least I finally have a much clearer picture of what is still going wrong…
The common setup passed: all seven expected participants were visible, and 22 complete snapshots kept the shared basis valid for more than 20 seconds. Then Scope A ran its three 120-second windows. All three failed. There were 14 new TX send errors, and the diagnostic counters placed them in the wifi_handoff ENOMEM stage. That tells me where the error was recorded, but not yet why it happens or whether it is fixed. MMWAVE2 also became stale in parts of the run, and several RX requests were missing, so none of the historical comparisons could count as a valid PASS.
Scope B stopped itself at the safety gate when the source binding became inconsistent and RX2 was already 5.044 seconds old. This is frustrating, but the guard did exactly what it was supposed to do, it refused to turn an incomplete 120-second window into a result.
Next: decide how to continue the ENOMEM and source-binding issues before starting another acceptance run.
Comments 0
No comments yet. Be the first!
Sign in to join the conversation.